At the time of its development and production, the Condor pressure switch was built in accordance with the applicable, recognized rules of technology and is considered to be safe to operate. However, dangers can emanate from the pressure switch if it is operated improperly by unqualified personnel. or not as intended. is used. The safety information and the local legal regulations must be observed. The pressure switches are used to monitor and control processes, to switch pumps and compressors depending on the prevailing pressure.
For the MDR-5 with buttons, an overcurrent relay is mandatory (not included in the scope of delivery), otherwise the on/off switch Mechanics not working!
Technical data (DIN EN 60947-4-1):
Rated operational current le (Ue = 400 V) | 16A |
Rated operational power (AC 3) Ue =250 V (1~) / 400 V (3~) / 500 V (3~) |
2.5kW/ 5.5kW /4kW |
Rated frequency | 50Hz/ 60Hz |
Rated insulation voltage Ui | 500V |
conditional rated short-circuit current (Ue = 500 V) | 3kA |
Pollution level | 3 |
Protection class | I |
Mechanical life cycles | > 5 X 105 |
Max. Mechanical switching frequency Switching cycles/ h | 600 |
Contact life (AC 3) operations | > 1 X 105 |
Rated operating mode (class 120) switching cycles/ h | 120 |
Temperature range | -5°c to +80°c |
Type "2" NH00 / gl | 50A |
Contact material | Silverlay. |
Item net weight (kg) | 0.860000 |
---|---|
Edmac/OEM | OEM |
Package length (mm) | 200.00 |
Package height (mm) | 80.00 |
Package width (mm) | 120.00 |
Brand | Condor |
Stocked at Edmac | No |
Subcategory | Electronics & Instrumentation |
Condor series | MDR 5 |
ON/OFF Switch? | Only with additional relay |
Condor reference | 212980 |
Flange | G 1/2" Alu |
Pressure range (bar) | 2,5 - 16 |
Edmac reference | 3004680751 |
Cross references | 3004680751, 608005032 |